* Samsung HD204UI (2TB F4EG) disk vs smart
@ 2011-02-15 21:40 Eyal Lebedinsky
2011-02-15 22:00 ` Roman Mamedov
0 siblings, 1 reply; 2+ messages in thread
From: Eyal Lebedinsky @ 2011-02-15 21:40 UTC (permalink / raw)
To: linux-raid list
Some of you already know this, but I thought it warrants a reminder
(I did not know...).
For the last month I was chasing a problem with my new RAID where a
large number of mismatches was reported in my weekly scrub.
I confirmed that I really had some data corruption.
I managed to not lose critical data but it surely was an uneasy period.
I commissioned new disks, new controller, and moved from f13 to f14
around the same time.
In the end the problem turned out to be the disks. It seems that these
popular (cheap) disks have a firmware bug that causes bad writes if a
specific smart command is issued at the right (wrong) time.
There is a fw fix but I found it not widely advertised. It can be found
here
http://www.samsung.com/global/business/hdd/faqView.do?b2b_bbs_msg_id=386
Unfortunately it does *not* change the fw revision so you will not know
if your disk has the patch applied or not. I just applied it and so far
so good. My fw rev was (and still is) 1AQ10001.
FYI
--
Eyal Lebedinsky (eyal@eyal.emu.id.au)
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2011-02-15 22:00 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2011-02-15 21:40 Samsung HD204UI (2TB F4EG) disk vs smart Eyal Lebedinsky
2011-02-15 22:00 ` Roman Mamedov
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox