* [PATCH] serial: 8250: don't bind to SMSC IrCC IR port
@ 2015-08-02 21:11 Maciej S. Szmigiero
0 siblings, 0 replies; only message in thread
From: Maciej S. Szmigiero @ 2015-08-02 21:11 UTC (permalink / raw)
To: linux-serial; +Cc: Greg Kroah-Hartman, Jiri Slaby, Peter Hurley, linux-kernel
SMSC IrCC SIR/FIR port should not be bound to by
(legacy) serial driver so its own driver (smsc-ircc2)
can bind to it.
Signed-off-by: Maciej Szmigiero <mail@maciej.szmigiero.name>
---
drivers/tty/serial/8250/8250_pnp.c | 5 +++++
1 files changed, 5 insertions(+), 0 deletions(-)
diff --git a/drivers/tty/serial/8250/8250_pnp.c b/drivers/tty/serial/8250/8250_pnp.c
index 50a09cd..61fd3d3 100644
--- a/drivers/tty/serial/8250/8250_pnp.c
+++ b/drivers/tty/serial/8250/8250_pnp.c
@@ -364,6 +364,11 @@ static const struct pnp_device_id pnp_dev_table[] = {
/* Winbond CIR port, should not be probed. We should keep track
of it to prevent the legacy serial driver from probing it */
{ "WEC1022", CIR_PORT },
+ /*
+ * SMSC IrCC SIR/FIR port, should not be probed by serial driver
+ * as well so its own driver can bind to it.
+ */
+ { "SMCF010", CIR_PORT },
{ "", 0 }
};
^ permalink raw reply related [flat|nested] only message in thread
only message in thread, other threads:[~2015-08-02 21:11 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2015-08-02 21:11 [PATCH] serial: 8250: don't bind to SMSC IrCC IR port Maciej S. Szmigiero
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox