* [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request
@ 2026-11-22 19:11 Andrew Stellman
2026-11-26 8:57 ` Leon Romanovsky
2026-11-26 14:40 ` Bernard Metzler
0 siblings, 2 replies; 3+ messages in thread
From: Andrew Stellman @ 2026-11-22 19:11 UTC (permalink / raw)
To: Bernard Metzler
Cc: Jason Gunthorpe, Leon Romanovsky, linux-rdma, linux-kernel
siw_init_rresp() queues an inbound RDMA Read Request in the inbound read
queue (IRQ) when the TX work request is busy. For a zero length Read
Request the IRQ entry has num_sge 0, and siw_activate_tx() then leaves
wqe->sqe.sge[0] as the previous work request left it.
siw_qp_sq_proc_tx() sets num_sge to 1 for every Read Response, so the
Read Response is built from the previous work request's sge[0]. RFC
5040, section 5.2.1, requires a zero length Read Response.
A plain TCP peer that speaks MPA rev 1 sent two Read Requests in one
write(): 64 bytes from an MR with remote read access, then a zero
length Read Request. The second Read Response carried the same 64
bytes of the MR:
Read Response, sink STag 0x11110000: 64 bytes "SIW016-REMOTE-RD..."
Read Response, sink STag 0x22220000: 64 bytes "SIW016-REMOTE-RD..."
When the zero length Read Request was sent 500 ms after the first one,
its Read Response had no payload.
Copy sge[0] from the IRQ entry whatever its length, as the immediate
path in siw_init_rresp() does. With this change the second Read
Response has no payload in both cases.
The issue was found by Claude Opus 5.5 running Quality Playbook, an
LLM-driven code review tool:
https://github.com/andrewstellman/quality-playbook
The fix and this changelog were drafted with Claude Opus 5.5 and
reviewed by me.
Fixes: f29dd55b0236 ("rdma/siw: queue pair methods")
Signed-off-by: Andrew Stellman <astellman@stellman-greene.com>
---
Tested in QEMU on v7.4-rc3 with KASAN, with a plain TCP peer that speaks
MPA rev 1. A reproducer is available on request.
drivers/infiniband/sw/siw/siw_qp.c | 17 +++++++++--------
1 file changed, 9 insertions(+), 8 deletions(-)
diff --git a/drivers/infiniband/sw/siw/siw_qp.c b/drivers/infiniband/sw/siw/siw_qp.c
index bb780e3904a..f3eb1c85f3e 100644
--- a/drivers/infiniband/sw/siw/siw_qp.c
+++ b/drivers/infiniband/sw/siw/siw_qp.c
@@ -972,14 +972,15 @@ int siw_activate_tx(struct siw_qp *qp)
/* start READ RESPONSE */
wqe->sqe.opcode = SIW_OP_READ_RESPONSE;
wqe->sqe.flags = 0;
- if (irqe->num_sge) {
- wqe->sqe.num_sge = 1;
- wqe->sqe.sge[0].length = irqe->sge[0].length;
- wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
- wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
- } else {
- wqe->sqe.num_sge = 0;
- }
+ /*
+ * Copy sge[0] also for a zero length Read Request. The TX path
+ * sends sge[0] of every Read Response, and the previous work
+ * request's sge[0] must not be sent in its place.
+ */
+ wqe->sqe.num_sge = irqe->num_sge;
+ wqe->sqe.sge[0].length = irqe->sge[0].length;
+ wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
+ wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
/* Retain original RREQ's message sequence number for
* potential error reporting cases.
--
2.43.0
^ permalink raw reply related [flat|nested] 3+ messages in thread* Re: [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request
2026-11-22 19:11 [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request Andrew Stellman
@ 2026-11-26 8:57 ` Leon Romanovsky
2026-11-26 14:40 ` Bernard Metzler
1 sibling, 0 replies; 3+ messages in thread
From: Leon Romanovsky @ 2026-11-26 8:57 UTC (permalink / raw)
To: Bernard Metzler, Andrew Stellman
Cc: Jason Gunthorpe, linux-rdma, linux-kernel
On Sun, 22 Nov 2026 14:11:22 -0500, Andrew Stellman wrote:
> siw_init_rresp() queues an inbound RDMA Read Request in the inbound read
> queue (IRQ) when the TX work request is busy. For a zero length Read
> Request the IRQ entry has num_sge 0, and siw_activate_tx() then leaves
> wqe->sqe.sge[0] as the previous work request left it.
> siw_qp_sq_proc_tx() sets num_sge to 1 for every Read Response, so the
> Read Response is built from the previous work request's sge[0]. RFC
> 5040, section 5.2.1, requires a zero length Read Response.
>
> [...]
Applied, thanks!
[1/1] RDMA/siw: Don't send stale data for a queued zero length Read Request
https://git.kernel.org/rdma/rdma/c/da570e4488d197
Best regards,
--
Leon Romanovsky <leon@kernel.org>
^ permalink raw reply [flat|nested] 3+ messages in thread* Re: [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request
2026-11-22 19:11 [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request Andrew Stellman
2026-11-26 8:57 ` Leon Romanovsky
@ 2026-11-26 14:40 ` Bernard Metzler
1 sibling, 0 replies; 3+ messages in thread
From: Bernard Metzler @ 2026-11-26 14:40 UTC (permalink / raw)
To: Andrew Stellman
Cc: Jason Gunthorpe, Leon Romanovsky, linux-rdma, linux-kernel
On 22.11.2026 20:11, Andrew Stellman wrote:
> siw_init_rresp() queues an inbound RDMA Read Request in the inbound read
> queue (IRQ) when the TX work request is busy. For a zero length Read
> Request the IRQ entry has num_sge 0, and siw_activate_tx() then leaves
> wqe->sqe.sge[0] as the previous work request left it.
> siw_qp_sq_proc_tx() sets num_sge to 1 for every Read Response, so the
> Read Response is built from the previous work request's sge[0]. RFC
> 5040, section 5.2.1, requires a zero length Read Response.
>
> A plain TCP peer that speaks MPA rev 1 sent two Read Requests in one
> write(): 64 bytes from an MR with remote read access, then a zero
> length Read Request. The second Read Response carried the same 64
> bytes of the MR:
>
> Read Response, sink STag 0x11110000: 64 bytes "SIW016-REMOTE-RD..."
> Read Response, sink STag 0x22220000: 64 bytes "SIW016-REMOTE-RD..."
>
> When the zero length Read Request was sent 500 ms after the first one,
> its Read Response had no payload.
>
> Copy sge[0] from the IRQ entry whatever its length, as the immediate
> path in siw_init_rresp() does. With this change the second Read
> Response has no payload in both cases.
>
> The issue was found by Claude Opus 5.5 running Quality Playbook, an
> LLM-driven code review tool:
> https://github.com/andrewstellman/quality-playbook
> The fix and this changelog were drafted with Claude Opus 5.5 and
> reviewed by me.
>
> Fixes: f29dd55b0236 ("rdma/siw: queue pair methods")
> Signed-off-by: Andrew Stellman <astellman@stellman-greene.com>
> ---
> Tested in QEMU on v7.4-rc3 with KASAN, with a plain TCP peer that speaks
> MPA rev 1. A reproducer is available on request.
>
> drivers/infiniband/sw/siw/siw_qp.c | 17 +++++++++--------
> 1 file changed, 9 insertions(+), 8 deletions(-)
>
> diff --git a/drivers/infiniband/sw/siw/siw_qp.c b/drivers/infiniband/sw/siw/siw_qp.c
> index bb780e3904a..f3eb1c85f3e 100644
> --- a/drivers/infiniband/sw/siw/siw_qp.c
> +++ b/drivers/infiniband/sw/siw/siw_qp.c
> @@ -972,14 +972,15 @@ int siw_activate_tx(struct siw_qp *qp)
> /* start READ RESPONSE */
> wqe->sqe.opcode = SIW_OP_READ_RESPONSE;
> wqe->sqe.flags = 0;
> - if (irqe->num_sge) {
> - wqe->sqe.num_sge = 1;
> - wqe->sqe.sge[0].length = irqe->sge[0].length;
> - wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
> - wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
> - } else {
> - wqe->sqe.num_sge = 0;
> - }
> + /*
> + * Copy sge[0] also for a zero length Read Request. The TX path
> + * sends sge[0] of every Read Response, and the previous work
> + * request's sge[0] must not be sent in its place.
> + */
> + wqe->sqe.num_sge = irqe->num_sge;
> + wqe->sqe.sge[0].length = irqe->sge[0].length;
> + wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
> + wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
>
Sorry for the late reply. And many thanks for catching this one!
Actually, setting num_sge here is of no effect since alway set to
1 during RRESPONSE processing in siw_qp_sq_proc_tx().
But thats just fine as it is now.
Acked-by: Bernard Metzler <bernard.metzler@linux.dev>
> /* Retain original RREQ's message sequence number for
> * potential error reporting cases.
^ permalink raw reply [flat|nested] 3+ messages in thread
end of thread, other threads:[~2026-11-26 14:40 UTC | newest]
Thread overview: 3+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-11-22 19:11 [PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request Andrew Stellman
2026-11-26 8:57 ` Leon Romanovsky
2026-11-26 14:40 ` Bernard Metzler
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox