* [PATCH net 0/2] vmxnet3: fix native XDP crash on oversized frames and XDP loss on reset
@ 2026-11-22 0:28 Philipp Sudakas
2026-11-22 0:28 ` [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer Philipp Sudakas
2026-11-22 0:28 ` [PATCH net 2/2] vmxnet3: keep the XDP program across device resets Philipp Sudakas
0 siblings, 2 replies; 5+ messages in thread
From: Philipp Sudakas @ 2026-11-22 0:28 UTC (permalink / raw)
To: Ronak Doshi, Broadcom internal kernel review list; +Cc: netdev, Philipp Sudakas
Two bugs in native XDP mode of vmxnet3. The first lets a single frame
from any host on the same L2 segment crash the guest; the second makes
the driver silently stop running XDP after any device reset and leaks
the program reference.
Patch 1: a frame that does not fit in one XDP rx buffer (sop without
eop) reaches the skb path, which takes the page_pool page for an skb:
kernel BUG in skb_put(). With MTU 1500 and an XDP program attached, a
single untagged frame of 1523..1526 bytes is enough.
Patch 2: vmxnet3_rq_cleanup_all() clears xdp_bpf_prog on every quiesce
(MTU change, down/up, ring resize, reset). XDP stops being called while
the program is still reported as attached, and it is never released.
Reproduced with stock modules on Debian kernels 6.12.113, 6.12.117 and
7.2.12 (7.2.12 untainted), VMware virtual hardware version 20. Both
code paths are unchanged in mainline as of e572847ee4d0. A small
reproducer (raw frame sender and an XDP_PASS counter program) is
available on request.
Testing:
- The same changes, backported to 6.12.113, were tested on the same
setup: frames of MTU + 23 and MTU + 30 (VLAN tagged) are dropped and
counted in drop_total at MTU 1400 and 1500; frames up to MTU + 22
still reach XDP; after an MTU change, down/up and an rx ring resize
the same program keeps running; MTU 9000 is refused while XDP is
attached; after detach the program is freed. A stream of 5000
oversized frames mixed with 5000 normal ones gave exactly 5000 XDP
passes and 5000 drops, with no kernel warnings. That test module also
carried a separate change to NAPI budget accounting for non-PASS XDP
verdicts, which will be sent on its own.
- On mainline the patches apply to e572847ee4d0 and vmxnet3_drv.c
builds with W=1 without warnings; they were not run-tested on a
mainline kernel.
Known limit not addressed here: with an MTU between about 3051 and
VMXNET3_XDP_MAX_MTU, normal frames already need more than one buffer,
and with this series they are dropped instead of crashing.
The problems were found and analysed, and the patches drafted, with
the help of an AI coding assistant; reproduction and testing were run
on the reporter's lab systems.
REPORTER NAME (2):
vmxnet3: drop XDP frames that do not fit in one rx buffer
vmxnet3: keep the XDP program across device resets
drivers/net/vmxnet3/vmxnet3_drv.c | 24 ++++++++++++++++++++++--
1 file changed, 22 insertions(+), 2 deletions(-)
--
2.47.3
^ permalink raw reply [flat|nested] 5+ messages in thread
* [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer
2026-11-22 0:28 [PATCH net 0/2] vmxnet3: fix native XDP crash on oversized frames and XDP loss on reset Philipp Sudakas
@ 2026-11-22 0:28 ` Philipp Sudakas
2026-11-23 1:06 ` netdev-bot+sashiko
2026-11-22 0:28 ` [PATCH net 2/2] vmxnet3: keep the XDP program across device resets Philipp Sudakas
1 sibling, 1 reply; 5+ messages in thread
From: Philipp Sudakas @ 2026-11-22 0:28 UTC (permalink / raw)
To: Ronak Doshi, Broadcom internal kernel review list; +Cc: netdev, Philipp Sudakas
With XDP enabled, rx ring 0 buffers are page_pool pages and the device
is given a buffer length of MTU + 22 (skb_buf_size). The device still
accepts somewhat longer frames (observed: up to MTU + 26 untagged,
MTU + 30 with a VLAN tag) and splits them over two descriptors.
vmxnet3_rq_rx_complete() runs XDP only for completions with both sop
and eop set. A frame with sop but without eop falls through to the skb
path, which uses rbi->skb although, for a VMXNET3_RX_BUF_XDP buffer,
that union member holds the page. The result is a kernel BUG in
skb_put(), or at BUG_ON(ctx->skb != NULL || rbi->skb == NULL):
kernel BUG at net/core/skbuff.c:2637!
RIP: 0010:skb_put+0x3c/0x40
Call Trace:
<IRQ>
vmxnet3_rq_rx_complete+0x893/0x12b0 [vmxnet3]
vmxnet3_poll_rx_only+0x38/0xd0 [vmxnet3]
__napi_poll+0x2b/0x160
net_rx_action+0x336/0x420
One frame of MTU + 23 to MTU + 26 bytes from any host on the same L2
segment is enough to crash a guest that has a native XDP program
attached to a vmxnet3 interface.
XDP on vmxnet3 is single-buffer, so drop such frames: count them in
drop_total, reuse the head buffer and skip the body buffers, as the
existing allocation failure path does. Count the dropped frame against
the NAPI budget. The completions of one frame may span two polls, so
start each poll with skip_page_frags set when no frame is in progress
(rx_ctx.skb == NULL): a body buffer without a head can only belong to a
dropped frame.
The problem was found and analysed, and this patch drafted, with the
help of an AI coding assistant. It was reproduced and tested on the
reporter's lab systems as described in the cover letter.
Fixes: 54f00cce1178 ("vmxnet3: Add XDP support.")
Signed-off-by: Philipp Sudakas <filzador@gmail.com>
---
drivers/net/vmxnet3/vmxnet3_drv.c | 18 +++++++++++++++++-
1 file changed, 17 insertions(+), 1 deletion(-)
diff --git a/drivers/net/vmxnet3/vmxnet3_drv.c b/drivers/net/vmxnet3/vmxnet3_drv.c
index f8df83f..fb98eb7 100644
--- a/drivers/net/vmxnet3/vmxnet3_drv.c
+++ b/drivers/net/vmxnet3/vmxnet3_drv.c
@@ -1614,7 +1614,8 @@ vmxnet3_rq_rx_complete(struct vmxnet3_rx_queue *rq,
adapter->rx_prod_offset, adapter->rx_prod2_offset
};
u32 num_pkts = 0;
- bool skip_page_frags = false;
+ /* A frame dropped at its head may continue in the next poll. */
+ bool skip_page_frags = !rq->rx_ctx.skb;
bool encap_lro = false;
struct Vmxnet3_RxCompDesc *rcd;
struct vmxnet3_rx_ctx *ctx = &rq->rx_ctx;
@@ -1666,6 +1667,21 @@ vmxnet3_rq_rx_complete(struct vmxnet3_rx_queue *rq,
goto rcd_done;
}
+ if (rcd->sop && !rcd->eop &&
+ rbi->buf_type == VMXNET3_RX_BUF_XDP &&
+ !VMXNET3_RX_DATA_RING(adapter, rcd->rqID)) {
+ /* The frame did not fit one XDP buffer. XDP here is
+ * single-buffer and the head holds a page, not an skb:
+ * drop the frame, reuse the head, skip its body buffers.
+ * Count it against the budget like other XDP verdicts.
+ */
+ rq->stats.drop_total++;
+ ctx->skb = NULL;
+ skip_page_frags = true;
+ num_pkts++;
+ goto rcd_done;
+ }
+
if (rcd->sop && rcd->eop && vmxnet3_xdp_enabled(adapter)) {
struct sk_buff *skb_xdp_pass;
int act;
--
2.47.3
^ permalink raw reply related [flat|nested] 5+ messages in thread
* [PATCH net 2/2] vmxnet3: keep the XDP program across device resets
2026-11-22 0:28 [PATCH net 0/2] vmxnet3: fix native XDP crash on oversized frames and XDP loss on reset Philipp Sudakas
2026-11-22 0:28 ` [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer Philipp Sudakas
@ 2026-11-22 0:28 ` Philipp Sudakas
2026-11-23 1:06 ` netdev-bot+sashiko
1 sibling, 1 reply; 5+ messages in thread
From: Philipp Sudakas @ 2026-11-22 0:28 UTC (permalink / raw)
To: Ronak Doshi, Broadcom internal kernel review list; +Cc: netdev, Philipp Sudakas
vmxnet3_rq_cleanup_all() clears adapter->xdp_bpf_prog. It is called
from vmxnet3_quiesce_dev(), so on every MTU change, down/up, ring
resize, reset work and resume. After that the driver no longer runs
XDP, while the core still reports the program as attached, and the
driver's reference to the program is never dropped: a later detach
finds xdp_bpf_prog already NULL and returns early.
Seen on 6.12.117 and 7.2.12: after "ip link set dev X mtu 1400",
"ip link set dev X down; ip link set dev X up" or
"ethtool -G X rx 512", the attached program is no longer called, and
each detached program stays loaded.
Do not clear the pointer there. The program is exchanged and released
by vmxnet3_xdp_set(), which also runs when the device is unregistered.
Rx rings are then recreated in XDP mode after a reset, as
vmxnet3_xdp_enabled() stays true.
Since the program now survives an MTU change, reject an MTU above
VMXNET3_XDP_MAX_MTU while XDP is attached, as vmxnet3_xdp_set()
already refuses to attach a program at such an MTU.
The problem was found and analysed, and this patch drafted, with the
help of an AI coding assistant. It was reproduced and tested on the
reporter's lab systems as described in the cover letter.
Fixes: 54f00cce1178 ("vmxnet3: Add XDP support.")
Signed-off-by: Philipp Sudakas <filzador@gmail.com>
---
drivers/net/vmxnet3/vmxnet3_drv.c | 6 +++++-
1 file changed, 5 insertions(+), 1 deletion(-)
diff --git a/drivers/net/vmxnet3/vmxnet3_drv.c b/drivers/net/vmxnet3/vmxnet3_drv.c
index fb98eb7..e84bf11 100644
--- a/drivers/net/vmxnet3/vmxnet3_drv.c
+++ b/drivers/net/vmxnet3/vmxnet3_drv.c
@@ -2104,7 +2104,6 @@ vmxnet3_rq_cleanup_all(struct vmxnet3_adapter *adapter)
for (i = 0; i < adapter->num_rx_queues; i++)
vmxnet3_rq_cleanup(&adapter->rx_queue[i], adapter);
- rcu_assign_pointer(adapter->xdp_bpf_prog, NULL);
}
@@ -3663,6 +3662,11 @@ vmxnet3_change_mtu(struct net_device *netdev, int new_mtu)
struct vmxnet3_adapter *adapter = netdev_priv(netdev);
int err = 0;
+ if (vmxnet3_xdp_enabled(adapter) && new_mtu > VMXNET3_XDP_MAX_MTU) {
+ netdev_err(netdev, "MTU %d too large for XDP\n", new_mtu);
+ return -EINVAL;
+ }
+
/*
* Reset_work may be in the middle of resetting the device, wait for its
* completion.
--
2.47.3
^ permalink raw reply related [flat|nested] 5+ messages in thread
* Re: [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer
2026-11-22 0:28 ` [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer Philipp Sudakas
@ 2026-11-23 1:06 ` netdev-bot+sashiko
0 siblings, 0 replies; 5+ messages in thread
From: netdev-bot+sashiko @ 2026-11-23 1:06 UTC (permalink / raw)
To: filzador; +Cc: ronak.doshi, bcm-kernel-feedback-list, netdev, kuba
Thank you for your contribution! Sashiko AI review found 3 potential
issue(s) to consider.
Critical: 0 · High: 0 (1) · Medium: 1 · Low: 2
If you believe none of the issues are legitimate, please reply to each
issue of Medium severity or higher and explain why the AI is wrong.
If any of them are legitimate and you plan to respin, please let patchwork
know by including "pw-bot: cr" as a separate line at the end of your reply
(one such reply per series is enough).
- [Medium] The commit message says the XDP head buffer given to the
device is MTU + 22 (skb_buf_size).
- [Low] In vmxnet3_rq_rx_complete() (drivers/net/vmxnet3/vmxnet3_drv.c),
the new comment says "Count it against the budget like other XDP…
- [Low] A frame dropped by the new head-drop branch in
vmxnet3_rq_rx_complete() is counted twice in rq->stats.drop_total if…
Pre-existing issues:
- [High] This problem wasn't introduced by this patch, but the patch's
new poll-start logic relies on the invariant it breaks, and it can…
--
vmxnet3: drop XDP frames that do not fit in one rx buffer
With XDP enabled, a frame the device splits over a head and a body
descriptor used to reach the skb path in vmxnet3_rq_rx_complete(). That
path treated the page_pool page as an skb and crashed the guest. This
patch drops such frames at the head, skips their body buffers, and
starts each poll with skip_page_frags set when no frame is in progress.
> diff --git a/drivers/net/vmxnet3/vmxnet3_drv.c b/drivers/net/vmxnet3/vmxnet3_drv.c
> index f8df83f9965db..fb98eb7712584 100644
> --- a/drivers/net/vmxnet3/vmxnet3_drv.c
> +++ b/drivers/net/vmxnet3/vmxnet3_drv.c
> @@ -1614,7 +1614,8 @@ vmxnet3_rq_rx_complete(struct vmxnet3_rx_queue *rq,
> adapter->rx_prod_offset, adapter->rx_prod2_offset
> };
> u32 num_pkts = 0;
> - bool skip_page_frags = false;
> + /* A frame dropped at its head may continue in the next poll. */
> + bool skip_page_frags = !rq->rx_ctx.skb;
[Severity: High]
This is a pre-existing issue and was not introduced by this patch.
However, this new line assumes rq->rx_ctx.skb is NULL whenever no frame
is in progress, and the data ring XDP path can break that.
For a data ring completion with XDP enabled, VMXNET3_GET_RING_IDX()
returns 0, so rbi points into rq->buf_info[0]. vmxnet3_rq_init() marked
that entry VMXNET3_RX_BUF_XDP, so its union holds a struct page pointer.
The sop block in vmxnet3_rq_rx_complete() still does:
skip_page_frags = false;
ctx->skb = rbi->skb;
...
if (rxDataRingUsed && vmxnet3_xdp_enabled(adapter)) {
...
if (act == XDP_PASS) {
ctx->skb = skb_xdp_pass;
goto sop_done;
}
need_flush |= act == XDP_REDIRECT;
goto rcd_done;
}
On any verdict other than XDP_PASS, ctx->skb keeps the page pointer.
That includes an XDP_DROP firewall program. The stale value can carry
over into later polls.
Suppose the next completion has eop and err set. Would
vmxnet3_rx_error() then run this on a ring-owned page_pool page?
if (ctx->skb)
dev_kfree_skb_irq(ctx->skb);
With this patch, the stale non-NULL value also makes the next poll start
with skip_page_frags = false. An orphan non-sop body could then get past
BUG_ON(ctx->skb == NULL && !skip_page_frags) and reach
vmxnet3_append_frag() with the page treated as an skb.
Would it make sense to clear ctx->skb before that goto rcd_done? The
ring buffer XDP path already does this. Another option is to not assign
ctx->skb = rbi->skb for VMXNET3_RX_BUF_XDP buffers.
> bool encap_lro = false;
> struct Vmxnet3_RxCompDesc *rcd;
> struct vmxnet3_rx_ctx *ctx = &rq->rx_ctx;
> @@ -1666,6 +1667,21 @@ vmxnet3_rq_rx_complete(struct vmxnet3_rx_queue *rq,
> goto rcd_done;
> }
>
> + if (rcd->sop && !rcd->eop &&
> + rbi->buf_type == VMXNET3_RX_BUF_XDP &&
> + !VMXNET3_RX_DATA_RING(adapter, rcd->rqID)) {
[Severity: Medium]
The commit message says:
the device is given a buffer length of MTU + 22 (skb_buf_size)
Does that hold for larger MTUs? vmxnet3_adjust_rx_ring_size() caps
skb_buf_size at VMXNET3_MAX_SKB_BUF_SIZE (3072) on v7:
adapter->skb_buf_size = min((int)adapter->netdev->mtu + VMXNET3_MAX_ETH_HDR_SIZE,
VMXNET3_MAX_SKB_BUF_SIZE);
Before v7 it sets skb_buf_size = VMXNET3_MAX_SKB_BUF_SIZE once the MTU is
above 3050. vmxnet3_rq_init() then uses that value as the length of the
VMXNET3_RX_BUF_XDP head buffers.
vmxnet3_xdp_set() only rejects netdev->mtu > VMXNET3_XDP_MAX_MTU, which
is about 3494 on x86_64.
Take XDP attached with an MTU of roughly 3059 to 3494. Won't every
full-sized frame (MTU + 14 > 3072) be split into a head and a body, and
then be dropped silently by this branch? That would drop all full-MTU
traffic on such an interface, not only the MTU + 23 to MTU + 26 frames
the commit message describes.
The later commit "vmxnet3: keep the XDP program across device resets"
adds an XDP check to vmxnet3_change_mtu(). It uses the same
VMXNET3_XDP_MAX_MTU bound, though, so this MTU range still seems to be
accepted.
Could XDP head buffers get a device length based on
VMXNET3_XDP_MAX_FRSIZE instead? Alternatively, could XDP be rejected when
MTU + VMXNET3_MAX_ETH_HDR_SIZE > skb_buf_size?
> + /* The frame did not fit one XDP buffer. XDP here is
> + * single-buffer and the head holds a page, not an skb:
> + * drop the frame, reuse the head, skip its body buffers.
> + * Count it against the budget like other XDP verdicts.
> + */
> + rq->stats.drop_total++;
[Severity: Low]
Can a frame dropped here be counted twice in drop_total? Suppose its
eop body completion has rcd->err set. This check at the top of the loop
runs before the skip_page_frags handling:
if (unlikely(rcd->eop && rcd->err)) {
vmxnet3_rx_error(rq, rcd, ctx, adapter);
goto rcd_done;
}
vmxnet3_rx_error() then increments rq->stats.drop_total again, without
any condition. vmxnet3_get_stats64() reports drop_total as rx_dropped.
The skb allocation failure path already has the same double count, so
this adds a second case. Also, the comment in vmxnet3_rx_error() says
ctx->skb may be NULL only for the first and only desc of a packet. With
this patch, that no longer covers every case.
> + ctx->skb = NULL;
> + skip_page_frags = true;
> + num_pkts++;
[Severity: Low]
Is the comment "Count it against the budget like other XDP verdicts"
accurate? After vmxnet3_process_xdp() returns a verdict other than
XDP_PASS, vmxnet3_rq_rx_complete() does:
ctx->skb = NULL;
need_flush |= act == XDP_REDIRECT;
goto rcd_done;
and num_pkts is not incremented. The same goes for the data ring path
after vmxnet3_process_xdp_small(), and for the allocation failure drop
path that this branch says it copies. Only XDP_PASS is counted, later,
after sop_done.
That makes this the only drop path that uses up NAPI budget. Should the
comment and the commit message be adjusted, or should the accounting be
made consistent?
> + goto rcd_done;
> + }
> +
[ ... ]
--
Sashiko AI review · https://netdev-ai.bots.linux.dev/sashiko/#/patchset/20261122002847.616-1-filzador%40gmail.com
^ permalink raw reply [flat|nested] 5+ messages in thread
* Re: [PATCH net 2/2] vmxnet3: keep the XDP program across device resets
2026-11-22 0:28 ` [PATCH net 2/2] vmxnet3: keep the XDP program across device resets Philipp Sudakas
@ 2026-11-23 1:06 ` netdev-bot+sashiko
0 siblings, 0 replies; 5+ messages in thread
From: netdev-bot+sashiko @ 2026-11-23 1:06 UTC (permalink / raw)
To: filzador; +Cc: ronak.doshi, bcm-kernel-feedback-list, netdev, kuba
Thank you for your contribution! Sashiko AI review found 1 potential
issue(s) to consider.
Critical: 1 · High: 0 · Medium: 0 · Low: 0
If you believe none of the issues are legitimate, please reply to each
issue of Medium severity or higher and explain why the AI is wrong.
If any of them are legitimate and you plan to respin, please let patchwork
know by including "pw-bot: cr" as a separate line at the end of your reply
(one such reply per series is enough).
- [Critical] On a failed XDP attach, the patch leaves a dangling bpf_prog
pointer in adapter->xdp_bpf_prog.
--
vmxnet3: keep the XDP program across device resets
This patch stops vmxnet3_rq_cleanup_all() from clearing
adapter->xdp_bpf_prog. The attached XDP program then survives the
quiesce and reset paths, such as MTU changes, down/up and ring resizes.
It also rejects MTU changes above VMXNET3_XDP_MAX_MTU while XDP is
attached.
> diff --git a/drivers/net/vmxnet3/vmxnet3_drv.c b/drivers/net/vmxnet3/vmxnet3_drv.c
> index fb98eb7712584..e84bf116a3baf 100644
> --- a/drivers/net/vmxnet3/vmxnet3_drv.c
> +++ b/drivers/net/vmxnet3/vmxnet3_drv.c
> @@ -2104,7 +2104,6 @@ vmxnet3_rq_cleanup_all(struct vmxnet3_adapter *adapter)
>
> for (i = 0; i < adapter->num_rx_queues; i++)
> vmxnet3_rq_cleanup(&adapter->rx_queue[i], adapter);
> - rcu_assign_pointer(adapter->xdp_bpf_prog, NULL);
> }
[Severity: Critical]
If an XDP attach fails inside vmxnet3_xdp_set(), does removing this line
leave a dangling program pointer in adapter->xdp_bpf_prog?
vmxnet3_xdp_set() publishes the new program and drops the old one before
it rebuilds and reactivates the device:
drivers/net/vmxnet3/vmxnet3_xdp.c:vmxnet3_xdp_set() {
...
vmxnet3_xdp_exchange_program(adapter, new_bpf_prog);
if (old_bpf_prog)
bpf_prog_put(old_bpf_prog);
...
err = vmxnet3_activate_dev(adapter);
if (err) {
NL_SET_ERR_MSG_MOD(extack,
"failed to activate device for XDP.");
return -EOPNOTSUPP;
}
...
}
When ndo_bpf fails, dev_xdp_install() in net/core/dev.c drops the
reference it took for the driver. It also does not record the program:
err = bpf_op(dev, &xdp);
if (err) {
if (prog)
bpf_prog_put(prog);
return err;
}
Before this patch, every error label in vmxnet3_activate_dev()
(activate_err, irq_err, rq_err) went through vmxnet3_rq_cleanup_all().
As a side effect, that reset adapter->xdp_bpf_prog to NULL. With the line
removed, nothing clears the pointer on that path.
vmxnet3_activate_dev() can fail in three ways:
- vmxnet3_rq_init_all() returns -ENOMEM because vmxnet3_create_pp() or
vmxnet3_rq_alloc_rx_buf() failed.
- vmxnet3_request_irqs() fails.
- The device rejects VMXNET3_CMD_ACTIVATE_DEV.
The vmxnet3_rq_create_all() error return in vmxnet3_xdp_set() leaves the
pointer in the same state.
Take an attach of program P on a running interface (old NULL, new P).
After this failure, adapter->xdp_bpf_prog == P, but neither the driver
nor the core holds a reference to P. Once userspace closes the prog fd,
P and its JIT image are freed.
vmxnet3_xdp_enabled() still returns true, so on the next down/up the rx
rings are rebuilt in XDP mode:
vmxnet3_open()
vmxnet3_activate_dev()
vmxnet3_rq_init_all()
vmxnet3_rq_init()
buf_type = VMXNET3_RX_BUF_XDP
Received packets then go from vmxnet3_rq_rx_complete() into
vmxnet3_process_xdp() or vmxnet3_process_xdp_small(), which do:
xdp_prog = rcu_dereference(rq->adapter->xdp_bpf_prog);
Could this run the freed program on every received packet?
A later attach of another program would see old_bpf_prog == P and call
bpf_prog_put() on the freed program. dev_xdp_uninstall() only calls
ndo_bpf for modes the core has recorded, so unregister would not clear
the stale pointer either.
The detach case (old P, new NULL) can still end up in the same state.
The same failure leaves the driver with NULL after P has already been
put, while the core still reports P as attached. That is the core/driver
disagreement the commit message describes.
The commit message says:
"The program is exchanged and released by vmxnet3_xdp_set()"
The error paths in vmxnet3_xdp_set() do not roll back the exchange,
though. Would it be safer to publish the new program and put the old one
only after vmxnet3_activate_dev() succeeds? Another option would be to
restore old_bpf_prog on the error paths without dropping its reference.
[ ... ]
--
Sashiko AI review · https://netdev-ai.bots.linux.dev/sashiko/#/patchset/20261122002847.616-1-filzador%40gmail.com
^ permalink raw reply [flat|nested] 5+ messages in thread
end of thread, other threads:[~2026-11-23 1:06 UTC | newest]
Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2026-11-22 0:28 [PATCH net 0/2] vmxnet3: fix native XDP crash on oversized frames and XDP loss on reset Philipp Sudakas
2026-11-22 0:28 ` [PATCH net 1/2] vmxnet3: drop XDP frames that do not fit in one rx buffer Philipp Sudakas
2026-11-23 1:06 ` netdev-bot+sashiko
2026-11-22 0:28 ` [PATCH net 2/2] vmxnet3: keep the XDP program across device resets Philipp Sudakas
2026-11-23 1:06 ` netdev-bot+sashiko