@ 2007-11-21 18:49 Moebius
  2007-11-21 21:52 ` [lm-sensors] how to choose the right sensor with an asus Moebius
                   ` (2 more replies)
  0 siblings, 3 replies; 4+ messages in thread
From: Moebius @ 2007-11-21 18:49 UTC (permalink / raw)
  To: lm-sensors

Bonjour,
I've recently bought this config : athlon64 x2 4400+ and the asus 
M2NPV-VM board.
There is 4 fan plugs on the board, but only two are connected, the cpu's 
one and the power one (with just 2 wires)

Sensors-detect give me this output :

Driver `smartbatt' (should be inserted):
   Detects correctly:
   * Bus `NVIDIA i2c adapter '
     Busdriver `UNKNOWN', I2C address 0x0b
     Chip `Smart Battery' (confidence: 5)

Driver `it87' (should be inserted):
   Detects correctly:
   * ISA bus, address 0x290
     Chip `ITE IT8716F Super IO Sensors' (confidence: 9)

Driver `k8temp' (should be inserted):
   Detects correctly:
   * Chip `AMD K8 thermal sensors' (confidence: 9)

So I insert the two modules needed (it87 and k8temp)

I'm following an ubuntu tuto here (in french... ) :
http://doc.ubuntu-fr.org/materiel/sensors

Well, then I try pwmconfig and it become very difficult :

First, jit's not too bad :

Found the following devices:
    hwmon0/device is k8temp
    hwmon1/device is it8716

Found the following PWM controls:
    hwmon1/device/pwm1
    hwmon1/device/pwm2
    hwmon1/device/pwm3

Found the following fan sensors:
    hwmon1/device/fan1_input     current speed: 3082 RPM
    hwmon1/device/fan2_input     current speed: 0 ... skipping!
    hwmon1/device/fan3_input     current speed: 1646 RPM

But when I try the command sensors to see which are the cpu sensor, the 
mb sensor ... I get something a bit confusing :

k8temp-pci-00c3
Adapter: PCI adapter
Core0 Temp:
               -6°C
Core0 Temp:
              -11°C
Core1 Temp:
               +5°C
Core1 Temp:
              -13°C

it8716-isa-0290
Adapter: ISA adapter
VCore:     +1.02 V  (min =  +0.00 V, max =  +4.08 V)
VDDR:      +3.31 V  (min =  +0.00 V, max =  +4.08 V)
+3.3V:     +0.00 V  (min =  +0.00 V, max =  +4.08 V)   ALARM
+5V:       +4.84 V  (min =  +0.00 V, max =  +6.85 V)
+12V:     +11.46 V  (min =  +0.00 V, max = +16.32 V)
in5:       +0.00 V  (min =  +0.00 V, max =  +4.08 V)   ALARM
in6:       +0.00 V  (min =  +0.00 V, max =  +4.08 V)   ALARM
5VSB:      +4.73 V  (min =  +0.00 V, max =  +6.85 V)
VBat:      +2.90 V
fan1:     3096 RPM  (min = 3245 RPM)                   ALARM
fan2:        0 RPM  (min = 3245 RPM)                   ALARM
fan3:     1646 RPM  (min =    0 RPM)
temp1:       +16°C  (low  =    -1°C, high =  +127°C)   sensor = diode
temp2:       +31°C  (low  =    -1°C, high =  +127°C)   sensor = 
thermistor
temp3:       +25°C  (low  =    -1°C, high =  +127°C)   sensor = 
thermistor
vid:      +0.000 V

So I can't determine the sensor to assign the cpu fan, cause I can't see 
which is the good cpu temperature.

I've tried to search in the list but find nothing really simple, nor in 
the sensors.conf.eg

Well I'm a little confused, so if someone can help, it would be great

cordialement,



_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

^ permalink raw reply	[flat|nested] 4+ messages in thread

end of thread, other threads:[~2007-12-02 10:41 UTC | newest]

Thread overview: 4+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2007-11-21 18:49 [lm-sensors] how to choose the right sensor with an asus M2NPV-VM Moebius
2007-11-21 21:52 ` [lm-sensors] how to choose the right sensor with an asus Moebius
2007-11-23 10:51 ` Moebius
2007-12-02 10:41 ` Jean Delvare

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.