* Priozier for remote port on fibre channel devices
@ 2013-01-11 7:11 Andreas.Bleischwitz
2013-01-11 7:22 ` Hannes Reinecke
0 siblings, 1 reply; 6+ messages in thread
From: Andreas.Bleischwitz @ 2013-01-11 7:11 UTC (permalink / raw)
To: dm-devel
[-- Attachment #1.1: Type: text/plain, Size: 3751 bytes --]
Hello List,
I'm currently facing a problem with a storage virtualization device which
is located in two different datacenters and shows up as another path to a
configured SAN-LUN.
The virtualization device is from EMC² and is called V-PLEX.
So I have something like this:
DC A
Host ---VPLEX-DC A---LUN storage A
| |
..|...........|...................
| DC B |
------VPLEX-DC B---LUN storage B
The VPLEX device itself is for storage based mirroring and synchronizes
write access to storage A to storage B and the other way around.
My problem is, that the virtual LUN I get from the VPLEX does not have any
prioritization given by dm-multipath and looks like this:
mpath3 (36000144000000010e06d8f12ec30dfef) dm-9 EMC,Invista
[size=5.0G][features=1 queue_if_no_path][hwhandler=0][rw]
\_ round-robin 0 [prio=1][active]
\_ 5:0:1:2 sdad 65:208 [active][ready]
\_ 5:0:4:2 sdak 66:64 [active][ready]
\_ 5:0:5:2 sdap 66:144 [active][ready]
\_ 4:0:0:2 sdc 8:32 [active][ready]
\_ 4:0:1:2 sdh 8:112 [active][ready]
\_ 4:0:4:2 sdo 8:224 [active][ready]
\_ 4:0:5:2 sdt 65:48 [active][ready]
\_ 5:0:0:2 sdy 65:128 [active][ready]
That way, write access is made round-robin and access to the
"remote-devices" - device located in the other DC - creating duplicate
traffic through the
SAN switches as the access has to be routed to the remote VPLEX-B and it
will write to the local VPLEX-A.
I wanted to solve this problem by giving priorities to a path by its
remote-port - which is different for each connection to a SAN device.
Unfortunately
there currently doesn't exist any priorizer and I have to write one on my
own.
To make the definition flexible, I would like to have a file with a list
of port-wwns associated with a priority.
For versions shipped with RHEL5 this could be a simple shell script which
simply looks up the sysfs file structures of a given device. For RHEL6
this has to be
a binary library. So writing a binary version will make more sense than
maintaining two different solutions.
A P-o-c script I wrote runs fine on RHEL5 - althouh a bit slow - but shows
the results I wanted to see:
--------- script --------
#! /bin/bash
PRIO_DEF="/etc/dm-multipath-vplex.conf"
DEVICE=${1#/dev/*}
# find scsi-device address
SCSI_ADDR="$(basename $(readlink /sys/block/$DEVICE/device/scsi_device*)
)"
# 3:0:2:0
# remove trailing :0
SCSI_ADDR=${SCSI_ADDR%:*}
# 3:0:2
# change x:x:x to x:x-x
SCSI_ADDR=$(echo "$SCSI_ADDR" | sed -e 's/:\([0-9]\)$/-\1/' )
# get port_name for scsi-remote-port
RPORT=$(cat "/sys/class/fc_remote_ports/rport-$SCSI_ADDR/port_name")
# return prio
IGNORECASE=1
awk "/$RPORT/ { print \$1 }" $PRIO_DEF
------------------------------------------
---------- dm-multipath-vplex.conf --------
# VPLEX DC A
1 0x50001442606d8f00
1 0x50001442606d8f01
1 0x50001442606d8f02
1 0x50001442606d8f03
1 0x50001442706d8f00
1 0x50001442706d8f01
1 0x50001442706d8f02
1 0x50001442706d8f03
# VPLEX DC B
2 0x5000144260641900
2 0x5000144260641901
2 0x5000144260641902
2 0x5000144260641903
2 0x5000144270641900
2 0x5000144270641901
2 0x5000144270641902
2 0x5000144270641903
--------------------------------------------
Do you think that this solutions is worth including it as rport-prio into
device mappers source? My C language skills are a bit rusty, but I at
least managed to
find out the SCSI-address of a given device and build the sysfs-path to
the remote port.
The rest should also be manageable, but I wanted to ask as early a
possible to have it included into mainstream and get some feedback on
this.
Best regrads,
Andreas Bleischwitz
[-- Attachment #1.2: Type: text/html, Size: 7625 bytes --]
[-- Attachment #2: Type: text/plain, Size: 0 bytes --]
^ permalink raw reply [flat|nested] 6+ messages in thread
* Re: Priozier for remote port on fibre channel devices
2013-01-11 7:11 Priozier for remote port on fibre channel devices Andreas.Bleischwitz
@ 2013-01-11 7:22 ` Hannes Reinecke
2013-01-11 7:47 ` Andreas.Bleischwitz
0 siblings, 1 reply; 6+ messages in thread
From: Hannes Reinecke @ 2013-01-11 7:22 UTC (permalink / raw)
To: dm-devel
On 01/11/2013 08:11 AM,
Andreas.Bleischwitz@continental-corporation.com wrote:
> Hello List,
>
> I'm currently facing a problem with a storage virtualization device
> which is located in two different datacenters and shows up as
> another path to a configured SAN-LUN.
> The virtualization device is from EMC² and is called V-PLEX.
>
> So I have something like this:
>
> DC A
> Host ---VPLEX-DC A---LUN storage A
> | |
> ..|...........|...................
> | DC B |
> ------VPLEX-DC B---LUN storage B
>
> The VPLEX device itself is for storage based mirroring and
> synchronizes write access to storage A to storage B and the other
> way around.
>
> My problem is, that the virtual LUN I get from the VPLEX does not
> have any prioritization given by dm-multipath and looks like this:
>
> mpath3 (36000144000000010e06d8f12ec30dfef) dm-9 EMC,Invista
> [size=5.0G][features=1 queue_if_no_path][hwhandler=0][rw]
> \_ round-robin 0 [prio=1][active]
> \_ 5:0:1:2 sdad 65:208 [active][ready]
> \_ 5:0:4:2 sdak 66:64 [active][ready]
> \_ 5:0:5:2 sdap 66:144 [active][ready]
> \_ 4:0:0:2 sdc 8:32 [active][ready]
> \_ 4:0:1:2 sdh 8:112 [active][ready]
> \_ 4:0:4:2 sdo 8:224 [active][ready]
> \_ 4:0:5:2 sdt 65:48 [active][ready]
> \_ 5:0:0:2 sdy 65:128 [active][ready]
>
> That way, write access is made round-robin and access to the
> "remote-devices" - device located in the other DC - creating
> duplicate traffic through the
> SAN switches as the access has to be routed to the remote VPLEX-B
> and it will write to the local VPLEX-A.
>
> I wanted to solve this problem by giving priorities to a path by its
> remote-port - which is different for each connection to a SAN
> device. Unfortunately
> there currently doesn't exist any priorizer and I have to write one
> on my own.
> To make the definition flexible, I would like to have a file with a
> list of port-wwns associated with a priority.
>
> For versions shipped with RHEL5 this could be a simple shell script
> which simply looks up the sysfs file structures of a given device.
> For RHEL6 this has to be
> a binary library. So writing a binary version will make more sense
> than maintaining two different solutions.
>
Well, at least on SLES we're shipping a prioritizer named
'weightedpath' which does exactly this.
However, chances are that the VPLEX is supporting ALUA, so you might
want to use the 'alua' prioritizer here.
What is the output of 'sg_inq /dev/sdc' ?
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@suse.de +49 911 74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
^ permalink raw reply [flat|nested] 6+ messages in thread
* Re: Priozier for remote port on fibre channel devices
2013-01-11 7:22 ` Hannes Reinecke
@ 2013-01-11 7:47 ` Andreas.Bleischwitz
2013-01-11 8:06 ` Hannes Reinecke
0 siblings, 1 reply; 6+ messages in thread
From: Andreas.Bleischwitz @ 2013-01-11 7:47 UTC (permalink / raw)
Cc: dm-devel, dm-devel-bounces
[-- Attachment #1.1: Type: text/plain, Size: 4203 bytes --]
Hello Hannes,
sorry for top-posting, but crappy Notes is not really a good client for
mailing-list - at least I don't know how to avoid such mess.
The output is
[root@fru3710e ~]# sg_inq /dev/sdc
standard INQUIRY:
PQual=0 Device_type=0 RMB=0 version=0x04 [SPC-2]
[AERC=0] [TrmTsk=0] NormACA=1 HiSUP=1 Resp_data_format=2
SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0
EncServ=0 MultiP=1 (VS=1) [MChngr=0] [ACKREQQ=0] Addr16=0
[RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1
[SPI: Clocking=0x0 QAS=0 IUS=0]
length=193 (0xc1) Peripheral device type: disk
Vendor identification: EMC
Product identification: Invista
Product revision level: 5100
Unit serial number: CKM00xxxxxxxxx
and well, 'weightedpath' is also available in RHEL, but only queries for
the device name and the SCSI-address. I wanted to query the remote-port of
the storage-device - which is the frontend wwn of the storage device.
Cheers,
Andreas
From: Hannes Reinecke <hare@suse.de>
To: dm-devel@redhat.com,
Date: 11.01.2013 08:28
Subject: Re: [dm-devel] Priozier for remote port on fibre channel
devices
Sent by: dm-devel-bounces@redhat.com
On 01/11/2013 08:11 AM,
Andreas.Bleischwitz@continental-corporation.com wrote:
> Hello List,
>
> I'm currently facing a problem with a storage virtualization device
> which is located in two different datacenters and shows up as
> another path to a configured SAN-LUN.
> The virtualization device is from EMC² and is called V-PLEX.
>
> So I have something like this:
>
> DC A
> Host ---VPLEX-DC A---LUN storage A
> | |
> ..|...........|...................
> | DC B |
> ------VPLEX-DC B---LUN storage B
>
> The VPLEX device itself is for storage based mirroring and
> synchronizes write access to storage A to storage B and the other
> way around.
>
> My problem is, that the virtual LUN I get from the VPLEX does not
> have any prioritization given by dm-multipath and looks like this:
>
> mpath3 (36000144000000010e06d8f12ec30dfef) dm-9 EMC,Invista
> [size=5.0G][features=1 queue_if_no_path][hwhandler=0][rw]
> \_ round-robin 0 [prio=1][active]
> \_ 5:0:1:2 sdad 65:208 [active][ready]
> \_ 5:0:4:2 sdak 66:64 [active][ready]
> \_ 5:0:5:2 sdap 66:144 [active][ready]
> \_ 4:0:0:2 sdc 8:32 [active][ready]
> \_ 4:0:1:2 sdh 8:112 [active][ready]
> \_ 4:0:4:2 sdo 8:224 [active][ready]
> \_ 4:0:5:2 sdt 65:48 [active][ready]
> \_ 5:0:0:2 sdy 65:128 [active][ready]
>
> That way, write access is made round-robin and access to the
> "remote-devices" - device located in the other DC - creating
> duplicate traffic through the
> SAN switches as the access has to be routed to the remote VPLEX-B
> and it will write to the local VPLEX-A.
>
> I wanted to solve this problem by giving priorities to a path by its
> remote-port - which is different for each connection to a SAN
> device. Unfortunately
> there currently doesn't exist any priorizer and I have to write one
> on my own.
> To make the definition flexible, I would like to have a file with a
> list of port-wwns associated with a priority.
>
> For versions shipped with RHEL5 this could be a simple shell script
> which simply looks up the sysfs file structures of a given device.
> For RHEL6 this has to be
> a binary library. So writing a binary version will make more sense
> than maintaining two different solutions.
>
Well, at least on SLES we're shipping a prioritizer named
'weightedpath' which does exactly this.
However, chances are that the VPLEX is supporting ALUA, so you might
want to use the 'alua' prioritizer here.
What is the output of 'sg_inq /dev/sdc' ?
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@suse.de +49 911
74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
--
dm-devel mailing list
dm-devel@redhat.com
https://www.redhat.com/mailman/listinfo/dm-devel
[-- Attachment #1.2: Type: text/html, Size: 6974 bytes --]
[-- Attachment #2: Type: text/plain, Size: 0 bytes --]
^ permalink raw reply [flat|nested] 6+ messages in thread
* Re: Priozier for remote port on fibre channel devices
2013-01-11 7:47 ` Andreas.Bleischwitz
@ 2013-01-11 8:06 ` Hannes Reinecke
2013-01-11 8:18 ` Andreas.Bleischwitz
0 siblings, 1 reply; 6+ messages in thread
From: Hannes Reinecke @ 2013-01-11 8:06 UTC (permalink / raw)
To: dm-devel
On 01/11/2013 08:47 AM,
Andreas.Bleischwitz@continental-corporation.com wrote:
> Hello Hannes,
>
> sorry for top-posting, but crappy Notes is not really a good client
> for mailing-list - at least I don't know how to avoid such mess.
>
> The output is
>
> [root@fru3710e ~]# sg_inq /dev/sdc
> standard INQUIRY:
> PQual=0 Device_type=0 RMB=0 version=0x04 [SPC-2]
> [AERC=0] [TrmTsk=0] NormACA=1 HiSUP=1 Resp_data_format=2
> SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0
> EncServ=0 MultiP=1 (VS=1) [MChngr=0] [ACKREQQ=0] Addr16=0
> [RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1
> [SPI: Clocking=0x0 QAS=0 IUS=0]
> length=193 (0xc1) Peripheral device type: disk
> Vendor identification: EMC
> Product identification: Invista
> Product revision level: 5100
> Unit serial number: CKM00xxxxxxxxx
>
Hehe. No alua for you (TPGS=0).
But that's EMC for you; probably you should count yourself lucky
that it's not claiming compability to SCSI-2 ...
> and well, 'weightedpath' is also available in RHEL, but only queries
> for the device name and the SCSI-address. I wanted to query the
> remote-port of the storage-device - which is the frontend wwn of the
> storage device.
>
Why don't you use the 'by-path' symlinks for the device name in
weightedpath?
They'll include the target port WWN, so should give you what you want.
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@suse.de +49 911 74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
^ permalink raw reply [flat|nested] 6+ messages in thread
* Re: Priozier for remote port on fibre channel devices
2013-01-11 8:06 ` Hannes Reinecke
@ 2013-01-11 8:18 ` Andreas.Bleischwitz
2013-01-11 8:42 ` Hannes Reinecke
0 siblings, 1 reply; 6+ messages in thread
From: Andreas.Bleischwitz @ 2013-01-11 8:18 UTC (permalink / raw)
To: device-mapper development
[-- Attachment #1.1: Type: text/plain, Size: 2405 bytes --]
Thanks for the hint, that will at least work for RHEL6+. For RHEL5 I will
use the scripted version.
The only downside on that is, that I will have a long line for the
weightedpath regex definition as this has to be for each VPLEX-port.
At least I will have reduced the need to write something on my own ;)
Best regards,
Andreas
From: Hannes Reinecke <hare@suse.de>
To: dm-devel@redhat.com,
Date: 11.01.2013 09:08
Subject: Re: [dm-devel] Priozier for remote port on fibre channel
devices
Sent by: dm-devel-bounces@redhat.com
On 01/11/2013 08:47 AM,
Andreas.Bleischwitz@continental-corporation.com wrote:
> Hello Hannes,
>
> sorry for top-posting, but crappy Notes is not really a good client
> for mailing-list - at least I don't know how to avoid such mess.
>
> The output is
>
> [root@fru3710e ~]# sg_inq /dev/sdc
> standard INQUIRY:
> PQual=0 Device_type=0 RMB=0 version=0x04 [SPC-2]
> [AERC=0] [TrmTsk=0] NormACA=1 HiSUP=1 Resp_data_format=2
> SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0
> EncServ=0 MultiP=1 (VS=1) [MChngr=0] [ACKREQQ=0] Addr16=0
> [RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1
> [SPI: Clocking=0x0 QAS=0 IUS=0]
> length=193 (0xc1) Peripheral device type: disk
> Vendor identification: EMC
> Product identification: Invista
> Product revision level: 5100
> Unit serial number: CKM00xxxxxxxxx
>
Hehe. No alua for you (TPGS=0).
But that's EMC for you; probably you should count yourself lucky
that it's not claiming compability to SCSI-2 ...
> and well, 'weightedpath' is also available in RHEL, but only queries
> for the device name and the SCSI-address. I wanted to query the
> remote-port of the storage-device - which is the frontend wwn of the
> storage device.
>
Why don't you use the 'by-path' symlinks for the device name in
weightedpath?
They'll include the target port WWN, so should give you what you want.
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@suse.de +49 911
74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
--
dm-devel mailing list
dm-devel@redhat.com
https://www.redhat.com/mailman/listinfo/dm-devel
[-- Attachment #1.2: Type: text/html, Size: 4164 bytes --]
[-- Attachment #2: Type: text/plain, Size: 0 bytes --]
^ permalink raw reply [flat|nested] 6+ messages in thread
* Re: Priozier for remote port on fibre channel devices
2013-01-11 8:18 ` Andreas.Bleischwitz
@ 2013-01-11 8:42 ` Hannes Reinecke
0 siblings, 0 replies; 6+ messages in thread
From: Hannes Reinecke @ 2013-01-11 8:42 UTC (permalink / raw)
To: device-mapper development
On 01/11/2013 09:18 AM,
Andreas.Bleischwitz@continental-corporation.com wrote:
> Thanks for the hint, that will at least work for RHEL6+. For RHEL5 I
> will use the scripted version.
>
> The only downside on that is, that I will have a long line for the
> weightedpath regex definition as this has to be for each VPLEX-port.
> At least I will have reduced the need to write something on my own ;)
>
Or write you own udev rules to generate shorter names ...
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@suse.de +49 911 74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
^ permalink raw reply [flat|nested] 6+ messages in thread
end of thread, other threads:[~2013-01-11 8:42 UTC | newest]
Thread overview: 6+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2013-01-11 7:11 Priozier for remote port on fibre channel devices Andreas.Bleischwitz
2013-01-11 7:22 ` Hannes Reinecke
2013-01-11 7:47 ` Andreas.Bleischwitz
2013-01-11 8:06 ` Hannes Reinecke
2013-01-11 8:18 ` Andreas.Bleischwitz
2013-01-11 8:42 ` Hannes Reinecke