Discussion of the VIRTIO specification
 help / color / mirror / Atom feed
From: Christian Schoenebeck <qemu_oss@crudebyte.com>
To: Cornelia Huck <cohuck@redhat.com>
Cc: virtio-comment@lists.oasis-open.org,
	Stefan Hajnoczi <stefanha@redhat.com>, Greg Kurz <groug@kaod.org>,
	Dominique Martinet <asmadeus@codewreck.org>,
	Halil Pasic <pasic@linux.ibm.com>
Subject: [virtio-comment] Re: [PATCH v3 4/4] Add CCW configuration field "indirect_num"
Date: Fri, 18 Mar 2022 12:02:31 +0100	[thread overview]
Message-ID: <11686863.Z9n2BMzBuM@silver> (raw)
In-Reply-To: <87cziksm5h.fsf@redhat.com>

On Donnerstag, 17. März 2022 15:12:42 CET Cornelia Huck wrote:
> On Wed, Mar 16 2022, Christian Schoenebeck <qemu_oss@crudebyte.com> wrote:
> > This new CCW configuration field allows to negotiate a more fine
> > graded maximum lenght of indirect descriptor chains.
> > 
> > Bump CCW virtio revision to 3 and make the existence of this new
> > field "indirect_num" dependant on revision 3.
> > 
> > Fixes: https://github.com/oasis-tcs/virtio-spec/issues/122
> > Signed-off-by: Christian Schoenebeck <qemu_oss@crudebyte.com>
> > ---
> > 
> >  content.tex | 14 +++++++++++++-
> >  1 file changed, 13 insertions(+), 1 deletion(-)
> 
> (...)
> 
> > @@ -2581,12 +2583,17 @@ \subsubsection{Configuring a
> > Virtqueue}\label{sec:Virtio Transport Options / Vir> 
> >  struct vq_config_block {
> >  
> >          be16 index;
> >          be16 max_num;
> > 
> > +        be32 indirect_num; /* since virtio-ccw rev. 3 */
> 
> Maybe make it max_indirect_num (to mirror max_num?)

Right, that name appears indeed more appropriate here.

> >  };
> >  \end{lstlisting}
> >  
> >  The requested number of buffers for queue \field{index} is returned in
> >  \field{max_num}.
> > 
> > +Since revision 3, \field{indirect_num} exists, which is supposed to
> > reflect the +Queue Indirect Size (i.e. the maximum length of indirect
> > descriptor tables) +supported by device for this queue.
> 
> It still depends on the feature flag, though.
> 
> Maybe
> 
> "If revision 2 or lower is set, struct vq_config_block extends up to
> \field{max_num}.
> 
> If revision 3 or higher is set, struct vq_config_block extends to
> \field{max_indirect_num}. If VIRTIO_RING_F_INDIRECT_SIZE is negotiated,
> \field{indirect_max_num} contains the maximum Queue Indirect Size
> (i.e. the maximum length of indirect descriptor tables) supported by the
> device for this queue; otherwise, its contents are unpredictable."

Maybe rather something like this instead:

"Actual size of struct vq_config_block depends on the virtio-ccw revision.

If revision 2 or lower is set, struct vq_config_block extends up to
*including* \field{max_num}.

If revision 3 or higher is set, struct vq_config_block extends up to
*including* \field{max_indirect_num}. If VIRTIO_RING_F_INDIRECT_SIZE is 
negotiated, \field{indirect_max_num} contains the maximum Queue Indirect Size
(i.e. the maximum length of indirect descriptor tables) supported by the
device for this queue; otherwise, its contents are *undefined*."
 
> > +
> > 
> >  Afterwards, CCW_CMD_SET_VQ is issued by the driver to inform the
> >  device about the location used for its queue. The transmitted
> >  structure is
> > 
> > @@ -2599,6 +2606,7 @@ \subsubsection{Configuring a
> > Virtqueue}\label{sec:Virtio Transport Options / Vir> 
> >          be16 num;
> >          be64 driver;
> >          be64 device;
> > 
> > +        be32 indirect_num; /* since virtio-ccw rev. 3 */
> > 
> >  };
> >  \end{lstlisting}
> > 
> > @@ -2607,6 +2615,10 @@ \subsubsection{Configuring a
> > Virtqueue}\label{sec:Virtio Transport Options / Vir> 
> >  available area and used area for queue \field{index}, respectively. The
> >  actual virtqueue size (number of allocated buffers) is transmitted in
> >  \field{num}.> 
> > +Since revision 3, \field{indirect_num} exists, which is supposed to
> > reflect the +Queue Indirect Size (i.e. the maximum length of indirect
> > descriptor tables) +supported by driver for this queue.
> 
> Similar to above:
> 
> "If revision 2 or lower is set, struct vq_info_block extends up to
> \field{device}.
> 
> If revision 3 or higher is set, struct vq_info_block extends to
> \field{indirect_num}. If VIRTIO_RING_F_INDIRECT_SIZE is negotiated,
> the Queue Indirect Size (i.e. the maximum length of indirect descriptor
> tables) supported by the driver for this queue is transmitted in
> \field{indirect_num}."

Ditto.

> > +
> > 
> >  \devicenormative{\paragraph}{Configuring a Virtqueue}{Virtio Transport
> >  Options / Virtio over channel I/O / Device Initialization / Configuring
> >  a Virtqueue}
> >  
> >  \field{res0} is reserved and MUST be ignored by the device.
> 
> We should include a device normative statement:
> 
> "The device MUST NOT offer VIRTIO_RING_F_INDIRECT_SIZE, unless at least
> revision 3 is set, and therefore \field{max_indirect_num} respectively
> \field{indirect_num} are available."

Oh, you are suggesting two different names for those two fields? 
"max_indirect_num" vs. "indirect_num". If yes, why?

Otherwise about adding that normative statement in general here: sure, makes 
sense.

Best regards,
Christian Schoenebeck




This publicly archived list offers a means to provide input to the
OASIS Virtual I/O Device (VIRTIO) TC.

In order to verify user consent to the Feedback License terms and
to minimize spam in the list archive, subscription is required
before posting.

Subscribe: virtio-comment-subscribe@lists.oasis-open.org
Unsubscribe: virtio-comment-unsubscribe@lists.oasis-open.org
List help: virtio-comment-help@lists.oasis-open.org
List archive: https://lists.oasis-open.org/archives/virtio-comment/
Feedback License: https://www.oasis-open.org/who/ipr/feedback_license.pdf
List Guidelines: https://www.oasis-open.org/policies-guidelines/mailing-lists
Committee: https://www.oasis-open.org/committees/virtio/
Join OASIS: https://www.oasis-open.org/join/


  reply	other threads:[~2022-03-18 11:02 UTC|newest]

Thread overview: 39+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2022-03-16 13:44 [PATCH v3 0/4] Add VIRTIO_RING_F_INDIRECT_SIZE and queue_indirect_size Christian Schoenebeck
2022-03-16 13:47 ` [PATCH v3 1/4] Add VIRTIO_RING_F_INDIRECT_SIZE Christian Schoenebeck
2022-03-17 13:40   ` [virtio-comment] " Cornelia Huck
2022-03-18 10:45     ` Christian Schoenebeck
2022-03-18 16:03       ` [virtio-comment] " Cornelia Huck
2022-03-19  9:33   ` [virtio-comment] " Michael S. Tsirkin
2022-03-19 12:00     ` Christian Schoenebeck
2022-03-20 12:31       ` Michael S. Tsirkin
2022-03-20 13:32         ` Christian Schoenebeck
2022-03-20 13:55           ` Michael S. Tsirkin
2022-03-20 15:17             ` Christian Schoenebeck
2022-03-20 16:06               ` Michael S. Tsirkin
2022-03-20 16:07                 ` Michael S. Tsirkin
2022-03-20 17:43                 ` Christian Schoenebeck
2022-03-20 21:52                   ` Michael S. Tsirkin
2022-03-21  9:23                     ` Christian Schoenebeck
2022-03-21 22:13                       ` Michael S. Tsirkin
2022-03-23 10:20                         ` Christian Schoenebeck
2022-03-23 12:35                           ` Michael S. Tsirkin
2022-03-24  9:16                             ` Christian Schoenebeck
2022-03-24 10:36                               ` Michael S. Tsirkin
2022-03-24 11:11                                 ` Christian Schoenebeck
2022-03-24 11:16                                   ` Michael S. Tsirkin
2022-03-24 11:52                                     ` Christian Schoenebeck
2022-03-16 13:50 ` [PATCH v3 2/4] Add PCI configuration field "queue_indirect_size" Christian Schoenebeck
2022-03-16 14:41   ` [virtio-comment] " Christian Schoenebeck
2022-03-16 13:52 ` [PATCH v3 3/4] Add MMIO configuration register "QueueIndirectNum" Christian Schoenebeck
2022-03-16 13:55 ` [PATCH v3 4/4] Add CCW configuration field "indirect_num" Christian Schoenebeck
2022-03-17 14:12   ` [virtio-comment] " Cornelia Huck
2022-03-18 11:02     ` Christian Schoenebeck [this message]
2022-03-18 16:06       ` Halil Pasic
2022-03-19 10:12         ` Christian Schoenebeck
2022-03-21 16:36           ` Cornelia Huck
2022-03-22  1:56             ` Halil Pasic
2022-03-22  9:57               ` Cornelia Huck
2022-03-22 11:21                 ` Halil Pasic
2022-03-18 16:10       ` Cornelia Huck
2022-03-19 10:23         ` Christian Schoenebeck
2022-03-21 16:25           ` Cornelia Huck

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=11686863.Z9n2BMzBuM@silver \
    --to=qemu_oss@crudebyte.com \
    --cc=asmadeus@codewreck.org \
    --cc=cohuck@redhat.com \
    --cc=groug@kaod.org \
    --cc=pasic@linux.ibm.com \
    --cc=stefanha@redhat.com \
    --cc=virtio-comment@lists.oasis-open.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox