From: Vasant Hegde <vasant.hegde@amd.com>
To: <iommu@lists.linux.dev>, <joro@8bytes.org>
Cc: <will@kernel.org>, <robin.murphy@arm.com>,
<suravee.suthikulpanit@amd.com>, <jgg@ziepe.ca>,
<yi.l.liu@intel.com>, <baolu.lu@linux.intel.com>,
<kevin.tian@intel.com>, <jacob.pan@linux.microsoft.com>,
Vasant Hegde <vasant.hegde@amd.com>
Subject: [PATCH v3 08/12] iommu/amd: Pass page table type as param to pdom_setup_pgtable()
Date: Thu, 17 Oct 2024 14:01:33 +0000 [thread overview]
Message-ID: <20241017140137.6028-9-vasant.hegde@amd.com> (raw)
In-Reply-To: <20241017140137.6028-1-vasant.hegde@amd.com>
Current code forces v1 page table for UNMANAGED domain and global page
table type (amd_iommu_pgtable) for rest of paging domain.
Following patch series adds support for domain_alloc_paging() ops. Also
enhances domain_alloc_user() to allocate page table based on 'flags.
Hence pass page table type as parameter to pdomain_setup_pgtable(). So
that caller can decide right page table type. Also update
dma_max_address() to take pgtable as parameter.
Signed-off-by: Vasant Hegde <vasant.hegde@amd.com>
Reviewed-by: Jacob Pan <jacob.pan@linux.microsoft.com>
---
drivers/iommu/amd/iommu.c | 43 +++++++++++++++++----------------------
1 file changed, 19 insertions(+), 24 deletions(-)
diff --git a/drivers/iommu/amd/iommu.c b/drivers/iommu/amd/iommu.c
index 6285fd1afd50..cb6a72564c23 100644
--- a/drivers/iommu/amd/iommu.c
+++ b/drivers/iommu/amd/iommu.c
@@ -2286,28 +2286,13 @@ struct protection_domain *protection_domain_alloc(unsigned int type, int nid)
}
static int pdom_setup_pgtable(struct protection_domain *domain,
- unsigned int type)
+ unsigned int type, int pgtable)
{
struct io_pgtable_ops *pgtbl_ops;
- int pgtable;
- switch (type) {
/* No need to allocate io pgtable ops in passthrough mode */
- case IOMMU_DOMAIN_IDENTITY:
+ if (!(type & __IOMMU_DOMAIN_PAGING))
return 0;
- case IOMMU_DOMAIN_DMA:
- pgtable = amd_iommu_pgtable;
- break;
- /*
- * Force IOMMU v1 page table when allocating
- * domain for pass-through devices.
- */
- case IOMMU_DOMAIN_UNMANAGED:
- pgtable = AMD_IOMMU_V1;
- break;
- default:
- return -EINVAL;
- }
switch (pgtable) {
case AMD_IOMMU_V1:
@@ -2319,6 +2304,7 @@ static int pdom_setup_pgtable(struct protection_domain *domain,
default:
return -EINVAL;
}
+
pgtbl_ops =
alloc_io_pgtable_ops(pgtable, &domain->iop.pgtbl.cfg, domain);
if (!pgtbl_ops)
@@ -2327,9 +2313,9 @@ static int pdom_setup_pgtable(struct protection_domain *domain,
return 0;
}
-static inline u64 dma_max_address(void)
+static inline u64 dma_max_address(int pgtable)
{
- if (amd_iommu_pgtable == AMD_IOMMU_V1)
+ if (pgtable == AMD_IOMMU_V1)
return ~0ULL;
/* V2 with 4/5 level page table */
@@ -2342,7 +2328,8 @@ static bool amd_iommu_hd_support(struct amd_iommu *iommu)
}
static struct iommu_domain *do_iommu_domain_alloc(unsigned int type,
- struct device *dev, u32 flags)
+ struct device *dev,
+ u32 flags, int pgtable)
{
bool dirty_tracking = flags & IOMMU_HWPT_ALLOC_DIRTY_TRACKING;
struct protection_domain *domain;
@@ -2367,7 +2354,7 @@ static struct iommu_domain *do_iommu_domain_alloc(unsigned int type,
if (!domain)
return ERR_PTR(-ENOMEM);
- ret = pdom_setup_pgtable(domain, type);
+ ret = pdom_setup_pgtable(domain, type, pgtable);
if (ret) {
domain_id_free(domain->id);
kfree(domain);
@@ -2375,7 +2362,7 @@ static struct iommu_domain *do_iommu_domain_alloc(unsigned int type,
}
domain->domain.geometry.aperture_start = 0;
- domain->domain.geometry.aperture_end = dma_max_address();
+ domain->domain.geometry.aperture_end = dma_max_address(pgtable);
domain->domain.geometry.force_aperture = true;
domain->domain.pgsize_bitmap = domain->iop.pgtbl.cfg.pgsize_bitmap;
@@ -2393,8 +2380,16 @@ static struct iommu_domain *do_iommu_domain_alloc(unsigned int type,
static struct iommu_domain *amd_iommu_domain_alloc(unsigned int type)
{
struct iommu_domain *domain;
+ int pgtable = amd_iommu_pgtable;
+
+ /*
+ * Force IOMMU v1 page table when allocating
+ * domain for pass-through devices.
+ */
+ if (type == IOMMU_DOMAIN_UNMANAGED)
+ pgtable = AMD_IOMMU_V1;
- domain = do_iommu_domain_alloc(type, NULL, 0);
+ domain = do_iommu_domain_alloc(type, NULL, 0, pgtable);
if (IS_ERR(domain))
return NULL;
@@ -2412,7 +2407,7 @@ amd_iommu_domain_alloc_user(struct device *dev, u32 flags,
if ((flags & ~IOMMU_HWPT_ALLOC_DIRTY_TRACKING) || parent || user_data)
return ERR_PTR(-EOPNOTSUPP);
- return do_iommu_domain_alloc(type, dev, flags);
+ return do_iommu_domain_alloc(type, dev, flags, AMD_IOMMU_V1);
}
void amd_iommu_domain_free(struct iommu_domain *dom)
--
2.31.1
next prev parent reply other threads:[~2024-10-17 14:04 UTC|newest]
Thread overview: 45+ messages / expand[flat|nested] mbox.gz Atom feed top
2024-10-17 14:01 [PATCH v3 00/12] iommu: Domain allocation enhancements Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 01/12] iommu: Refactor __iommu_domain_alloc() Vasant Hegde
2024-10-21 7:29 ` Yi Liu
2024-10-21 9:10 ` Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 02/12] iommu: Introduce iommu_paging_domain_alloc_flags() Vasant Hegde
2024-10-18 3:29 ` Baolu Lu
2024-10-21 7:47 ` Yi Liu
2024-10-21 9:19 ` Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 03/12] iommu: Add new flag to explictly request PASID capable domain Vasant Hegde
2024-10-18 3:43 ` Baolu Lu
2024-10-18 12:43 ` Jason Gunthorpe
2024-10-21 5:02 ` Baolu Lu
2024-10-18 14:16 ` Jason Gunthorpe
2024-10-21 10:02 ` Vasant Hegde
2024-10-21 7:57 ` Yi Liu
2024-10-23 8:52 ` Vasant Hegde
2024-10-21 7:59 ` Yi Liu
2024-10-22 4:54 ` Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 04/12] iommu/arm-smmu-v3: Enhance domain_alloc_user() to allocate " Vasant Hegde
2024-10-18 14:23 ` Jason Gunthorpe
2024-10-21 8:57 ` Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 05/12] iommu/amd: Add helper function to check GIOSUP/GTSUP Vasant Hegde
2024-10-18 14:23 ` Jason Gunthorpe
2024-10-17 14:01 ` [PATCH v3 06/12] iommu/amd: Move V2 page table support check to early_amd_iommu_init() Vasant Hegde
2024-10-18 14:24 ` Jason Gunthorpe
2024-10-17 14:01 ` [PATCH v3 07/12] iommu/amd: Separate page table setup from domain allocation Vasant Hegde
2024-10-17 14:01 ` Vasant Hegde [this message]
2024-10-18 14:25 ` [PATCH v3 08/12] iommu/amd: Pass page table type as param to pdom_setup_pgtable() Jason Gunthorpe
2024-10-17 14:01 ` [PATCH v3 09/12] iommu/amd: Enhance amd_iommu_domain_alloc_user() Vasant Hegde
2024-10-18 14:27 ` Jason Gunthorpe
2024-10-21 9:00 ` Vasant Hegde
2024-10-22 7:48 ` Tian, Kevin
2024-10-23 8:47 ` Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 10/12] iommu/amd: Implement global identity domain Vasant Hegde
2024-10-17 14:01 ` [PATCH v3 11/12] iommu: Put domain allocation in __iommu_group_alloc_blocking_domain() Vasant Hegde
2024-10-18 4:02 ` Baolu Lu
2024-10-17 14:01 ` [PATCH v3 12/12] iommu: Create __iommu_alloc_identity_domain() Vasant Hegde
2024-10-18 4:04 ` Baolu Lu
2024-10-18 14:32 ` Jason Gunthorpe
2024-10-21 6:38 ` Vasant Hegde
2024-10-18 3:10 ` [PATCH v3 00/12] iommu: Domain allocation enhancements Baolu Lu
2024-10-18 12:50 ` Jason Gunthorpe
2024-10-21 9:08 ` Vasant Hegde
2024-10-22 7:50 ` Tian, Kevin
2024-10-23 8:48 ` Vasant Hegde
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20241017140137.6028-9-vasant.hegde@amd.com \
--to=vasant.hegde@amd.com \
--cc=baolu.lu@linux.intel.com \
--cc=iommu@lists.linux.dev \
--cc=jacob.pan@linux.microsoft.com \
--cc=jgg@ziepe.ca \
--cc=joro@8bytes.org \
--cc=kevin.tian@intel.com \
--cc=robin.murphy@arm.com \
--cc=suravee.suthikulpanit@amd.com \
--cc=will@kernel.org \
--cc=yi.l.liu@intel.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox