From: Manasi Navare <manasi.d.navare@intel.com>
To: intel-gfx@lists.freedesktop.org, dri-devel@lists.freedesktop.org
Cc: Rodrigo Vivi <rodrigo.vivi@intel.com>
Subject: [PATCH v8 18/19] drm/i915/dsc: Enable and disable appropriate power wells for VDSC
Date: Fri, 2 Nov 2018 14:31:37 -0700 [thread overview]
Message-ID: <20181102213138.301-19-manasi.d.navare@intel.com> (raw)
In-Reply-To: <20181102213138.301-1-manasi.d.navare@intel.com>
A separate power well 2 (PG2) is required for VDSC on eDP transcoder
whereas all other transcoders use the power wells associated with the
transcoders for VDSC.
This patch adds a helper to obtain correct power domain depending on
transcoder being used and enables/disables the power wells during
VDSC enabling/disabling.
v4:
* Get VDSC power domain only if compression en is set
in crtc_state (Ville, Imre)
v3:
* Call it intel_dsc_power_domain, add to
intel_ddi_get_power_domains (Ville)
v2:
* Fix tabs, const crtc_state, fix comments (Ville)
Suggested-by: Ville Syrjala <ville.syrjala@linux.intel.com>
Cc: Ville Syrjala <ville.syrjala@linux.intel.com>
Cc: Imre Deak <imre.deak@intel.com>
Cc: Rodrigo Vivi <rodrigo.vivi@intel.com>
Signed-off-by: Manasi Navare <manasi.d.navare@intel.com>
Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
---
drivers/gpu/drm/i915/intel_ddi.c | 6 ++++++
drivers/gpu/drm/i915/intel_drv.h | 2 ++
drivers/gpu/drm/i915/intel_vdsc.c | 25 +++++++++++++++++++++++++
3 files changed, 33 insertions(+)
diff --git a/drivers/gpu/drm/i915/intel_ddi.c b/drivers/gpu/drm/i915/intel_ddi.c
index bba08322afb7..82d78f2727d8 100644
--- a/drivers/gpu/drm/i915/intel_ddi.c
+++ b/drivers/gpu/drm/i915/intel_ddi.c
@@ -2126,6 +2126,12 @@ static u64 intel_ddi_get_power_domains(struct intel_encoder *encoder,
intel_port_is_tc(dev_priv, encoder->port))
domains |= BIT_ULL(intel_ddi_main_link_aux_domain(dig_port));
+ /*
+ * VDSC power is needed when DSC is enabled
+ */
+ if (crtc_state->dsc_params.compression_enable)
+ domains |= BIT_ULL(intel_dsc_power_domain(crtc_state));
+
return domains;
}
diff --git a/drivers/gpu/drm/i915/intel_drv.h b/drivers/gpu/drm/i915/intel_drv.h
index e537561b3d40..2d41dff6eed1 100644
--- a/drivers/gpu/drm/i915/intel_drv.h
+++ b/drivers/gpu/drm/i915/intel_drv.h
@@ -1859,6 +1859,8 @@ uint8_t intel_dp_dsc_get_slice_count(struct intel_dp *intel_dp, int mode_clock,
/* intel_vdsc.c */
int intel_dp_compute_dsc_params(struct intel_dp *intel_dp,
struct intel_crtc_state *pipe_config);
+enum intel_display_power_domain
+intel_dsc_power_domain(const struct intel_crtc_state *crtc_state);
static inline unsigned int intel_dp_unused_lane_mask(int lane_count)
{
diff --git a/drivers/gpu/drm/i915/intel_vdsc.c b/drivers/gpu/drm/i915/intel_vdsc.c
index 02102cd275fd..a25b71ae9b1c 100644
--- a/drivers/gpu/drm/i915/intel_vdsc.c
+++ b/drivers/gpu/drm/i915/intel_vdsc.c
@@ -581,6 +581,24 @@ int intel_dp_compute_dsc_params(struct intel_dp *intel_dp,
return 0;
}
+enum intel_display_power_domain
+intel_dsc_power_domain(const struct intel_crtc_state *crtc_state)
+{
+ enum transcoder cpu_transcoder = crtc_state->cpu_transcoder;
+
+ /*
+ * On ICL VDSC/joining for eDP transcoder uses a separate power well PW2
+ * This requires POWER_DOMAIN_TRANSCODER_EDP_VDSC power domain.
+ * For any other transcoder, VDSC/joining uses the power well associated
+ * with the pipe/transcoder in use. Hence another reference on the
+ * transcoder power domain will suffice.
+ */
+ if (cpu_transcoder == TRANSCODER_EDP)
+ return POWER_DOMAIN_TRANSCODER_EDP_VDSC;
+ else
+ return POWER_DOMAIN_TRANSCODER(cpu_transcoder);
+}
+
static void intel_configure_pps_for_dsc_encoder(struct intel_encoder *encoder,
const struct intel_crtc_state *crtc_state)
{
@@ -1020,6 +1038,10 @@ void intel_dsc_enable(struct intel_encoder *encoder,
if (!crtc_state->dsc_params.compression_enable)
return;
+ /* Enable Power wells for VDSC/joining */
+ intel_display_power_get(dev_priv,
+ intel_dsc_power_domain(crtc_state));
+
intel_configure_pps_for_dsc_encoder(encoder, crtc_state);
intel_dp_write_dsc_pps_sdp(encoder, crtc_state);
@@ -1072,4 +1094,7 @@ void intel_dsc_disable(const struct intel_crtc_state *old_crtc_state)
RIGHT_BRANCH_VDSC_ENABLE);
I915_WRITE(dss_ctl2_reg, dss_ctl2_val);
+ /* Disable Power wells for VDSC/joining */
+ intel_display_power_put(dev_priv,
+ intel_dsc_power_domain(old_crtc_state));
}
--
2.18.0
_______________________________________________
Intel-gfx mailing list
Intel-gfx@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/intel-gfx
next prev parent reply other threads:[~2018-11-02 21:31 UTC|newest]
Thread overview: 39+ messages / expand[flat|nested] mbox.gz Atom feed top
2018-11-02 21:31 [PATCH v8 00/19] DSC enabling remaining patches respin Manasi Navare
2018-11-02 21:31 ` [PATCH v8 01/19] drm/dsc: Define Display Stream Compression PPS infoframe Manasi Navare
2018-11-02 21:31 ` [PATCH v8 02/19] drm/dsc: Define VESA Display Stream Compression Capabilities Manasi Navare
2018-11-02 21:31 ` [PATCH v8 03/19] drm/dsc: Define Rate Control values that do not change over configurations Manasi Navare
2018-11-02 21:31 ` [PATCH v8 04/19] drm/dsc: Add helpers for DSC picture parameter set infoframes Manasi Navare
2018-11-06 1:38 ` Srivatsa, Anusha
2018-11-06 20:17 ` Manasi Navare
2018-11-02 21:31 ` [PATCH v8 05/19] drm/dsc: Define the DSC 1.1 and 1.2 Line Buffer depth constants Manasi Navare
2018-11-02 21:31 ` [PATCH v8 06/19] drm/i915/dp: Add DSC params and DSC config to intel_crtc_state Manasi Navare
2018-11-02 21:31 ` [PATCH v8 07/19] drm/i915/dp: Compute DSC pipe config in atomic check Manasi Navare
2018-11-03 2:09 ` Manasi Navare
2018-11-06 14:42 ` Ville Syrjälä
2018-11-06 20:37 ` Manasi Navare
2018-11-07 22:31 ` Manasi Navare
2018-11-06 22:41 ` Srivatsa, Anusha
2018-11-06 22:48 ` Manasi Navare
2018-11-02 21:31 ` [PATCH v8 08/19] drm/i915/dp: Do not enable PSR2 if DSC is enabled Manasi Navare
2018-11-02 21:31 ` [PATCH v8 09/19] drm/i915/dsc: Define & Compute VESA DSC params Manasi Navare
2018-11-02 21:31 ` [PATCH v8 10/19] drm/i915/dsc: Compute Rate Control parameters for DSC Manasi Navare
2018-11-06 14:33 ` Ville Syrjälä
2018-11-06 16:52 ` Manasi Navare
2018-11-06 17:00 ` Ville Syrjälä
2018-11-06 20:14 ` Manasi Navare
2018-11-06 20:30 ` Ville Syrjälä
2018-11-02 21:31 ` [PATCH v8 11/19] drm/i915/dp: Enable/Disable DSC in DP Sink Manasi Navare
2018-11-02 21:31 ` [PATCH v8 12/19] drm/i915/dsc: Add a power domain for VDSC on eDP/MIPI DSI Manasi Navare
2018-11-02 21:31 ` [PATCH v8 13/19] drm/i915/dp: Configure i915 Picture parameter Set registers during DSC enabling Manasi Navare
2018-11-06 14:36 ` Ville Syrjälä
2018-11-06 16:50 ` Manasi Navare
2018-11-02 21:31 ` [PATCH v8 14/19] drm/i915/dp: Use the existing write_infoframe() for DSC PPS SDPs Manasi Navare
2018-11-02 21:31 ` [PATCH v8 15/19] drm/i915/dp: Populate DSC PPS SDP and send PPS infoframes Manasi Navare
2018-11-02 21:31 ` [PATCH v8 16/19] drm/i915/dp: Configure Display stream splitter registers during DSC enable Manasi Navare
2018-11-02 21:31 ` [PATCH v8 17/19] drm/i915/dp: Disable DSC in source by disabling DSS CTL bits Manasi Navare
2018-11-02 21:31 ` Manasi Navare [this message]
2018-11-02 21:31 ` [PATCH v8 19/19] drm/i915/dsc: Add Per connector debugfs node for DSC support/enable Manasi Navare
2018-11-03 2:40 ` Manasi Navare
2018-11-02 21:51 ` ✗ Fi.CI.CHECKPATCH: warning for DSC enabling remaining patches respin Patchwork
2018-11-02 21:57 ` ✗ Fi.CI.SPARSE: " Patchwork
2018-11-02 22:30 ` ✗ Fi.CI.BAT: failure " Patchwork
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20181102213138.301-19-manasi.d.navare@intel.com \
--to=manasi.d.navare@intel.com \
--cc=dri-devel@lists.freedesktop.org \
--cc=intel-gfx@lists.freedesktop.org \
--cc=rodrigo.vivi@intel.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox